Process NMR Associates
PNA-WP-2026-HOPS-01-A1 · Section A11

A11. Critical Assessment and Recommendations

NMR Spectroscopy in the Analysis of Hops (Humulus lupulus L.) · Addendum A1: Direct qNMR and Chemometrics

A11.1 What a Reviewer or an Opposing Expert Would Raise

The objections that an expert reviewer, an accreditation assessor or an opposing expert witness would be most likely to raise against the quantitative results of this addendum are, in order of weight, the following. The absolute scale rests on a volatile transfer standard whose content is known to have fallen in one of the two bottles and whose stability between the calibration and the extractions was not monitored; the one independent check of the scale, the ICE-4 extract, failed by almost a factor of two, and the explanation offered for the failure, a transcription of the mass, is plausible but unproven. Each sample was extracted and measured once, so that the repeatability of the method, and with it the significance of any difference between two samples, is unknown; the same-cultivar pairs are lots of different age and provenance and are not replicates. The acquisition parameters other than the relaxation delay were not recorded, and the relaxation conditions of the calibration and sample spectra can be shown to be equivalent only by assumption. The declared α-acid contents with which the results were compared are nominal figures of unknown method and date, and agreement with them, although reassuring for the thirteen recent samples, is not validation. Two samples, the Belma 025 and the Magnum 026, carry labels or masses that are inconsistent with their spectra.

The assignment of the hydroxyl region is on firmer ground than in v1.1, because it now rests on resolved lines and exact windows as well as on statistics, but two points remain open: the identity of the δ 18.5 pair, which is fixed in proportion to the β-acid homologs but is apparently not measured as β-acid by the ICE-4 chromatographic assignment, and the fixed-window bias in the adhumulone–cohumulone split of concentrated extracts, which affects the cohumulone values of the Cryo pellets by several points.

For the chemometric results the principal objections are the size and structure of the data set, 49 samples of 38 cultivars with at most three lots of any cultivar; the confounding of region with cultivar genetics, breeding objective, product form and measurement campaign, which no statistical treatment of these samples can undo; the inference of the country of growth for 21 samples; and the multiplicity of models and pretreatments examined. The last has been addressed by nested validation and by permutation tests that include the selection of the best model, and the reported geographic accuracies, although some exceed their permutation distributions, are no better than those of a baseline built on three chemical descriptors; an opposing expert would not be able to use them to support a claim of origin, and they are not offered for that purpose. The UMAP and t-SNE maps are the most easily misread of the outputs, and they have been shown to preserve local neighborhoods less faithfully than a three-component PCA.

None of these objections undermines the relative measurements, the homolog fractions and the α/β ratios, which are independent of the calibration route and are supported by the ICE-4 composition to within a percentage point, or the chemotype structure, which is stable under every pretreatment and clustering method examined.

A11.2 Recommendations

It is recommended, first, that the absolute scale be put on a secure footing before the contents in Table A6 are issued in any report. The simplest course is the one recommended in v1.1: a gravimetrically prepared stock solution of dimethyl sulfone, about 5 mg mL⁻¹ in acid-free CDCl₃, used as the extraction solvent, with the quantity delivered to each vial recorded by mass rather than by volume and a relaxation delay of at least 25 s pending measurement of the T₁ values. The calibrant is then non-volatile and present in every tube, and TMS serves only as the chemical-shift reference; weighing the DMS directly into each vial is an equally sound alternative. If the transfer method is retained, each bottle should be calibrated at the start and the end of every batch, the drift between the two calibrations should be recorded and used as an acceptance criterion, the bottle should be kept closed and cold between uses, and the TMS integration window should be identical in calibration and sample spectra. In either case the ICE-4 extract should be carried through each batch with its mass and bottle recorded, with acceptance limits on the recovery of the certified α- and β-acid contents as well as on the cohumulone fraction and the α/β ratio.

Second, the method should be characterized as a method before it is used for decisions. Replicate extractions of a subset of samples, at least three extractions of each of three hops of different resin content on different days, would give the repeatability and intermediate precision; a second extraction of the residue of the first would establish the completeness of extraction; an inversion-recovery measurement on one extract would give the T₁ values of the hydroxyl protons, TMS and DMS; and the pulse angle, acquisition time, number of transients and temperature should be recorded with every spectrum. These are the elements that an ISO/IEC 17025 validation file would require.

Third, the integration should be adapted to the chemistry. The α-acid windows should follow the concentration-dependent shifts, either by setting the boundaries at the valleys of each spectrum or by fitting the three α-acid lines, and extracts of Cryo pellets and resin extracts should be prepared at about half the mass, so that their concentrations fall in the range of the pellet extracts. The β-acid totals should be reported as the sum of the major and minor tautomers, with the δ 18.5 pair reported separately until its identity is established by an exchange spectrum of purified β-acids or by spiking with a 4-deoxy-α-acid.

Fourth, if geographic authentication is the goal, the sampling must be designed for it: authenticated lots of the same cultivars grown in different regions, ten or more lots per cultivar and region over at least two harvests, with the NMR variables extended to the xanthohumol hydroxyl signal and supplemented by the measurements that are known to carry origin information, stable isotope ratios, elements and gas-chromatographic volatiles, and with class models rather than discriminant models validated on a harvest not used for training. Until such a set exists, the NMR data are best used for what they measure well: the homolog composition and α/β ratio as a check on the declared cultivar, the α- and β-acid contents as a check on the declared analysis once the scale is secured, and the ratio of oil to resin as an index of freshness.

Back to top