The first issue of this white paper, PNA-WP-2026-HOPS-01, and its revision 1.1 examined the hydroxyl region of the 300 MHz ¹H spectra of CDCl₃ extracts of 36 commercial hop samples, together with a five-sample combined HPLC–NMR study, and applied chemometric and machine-learning methods to the integrals. Three limitations of that material were stated repeatedly and governed every conclusion drawn from it. The integrals had been archived after division by the adlupulone signal, so that the absolute scale of the spectra had been lost and only the composition of the bitter-acid fraction could be analyzed; the integration windows were not available, so that the identity of each integral had to be inferred from its position in a list and from its statistical behavior; and no internal calibrant had been present, so that contents could not be obtained from the NMR data at all. It was concluded that no model built on relative integrals could stand in place of an internal standard, and the re-integration of the survey with one documented window set and with the integrals archived on an absolute scale was listed among the tasks reserved for a later version.
That task has now been carried out, and the data set has been enlarged. The spectra themselves have been supplied, each with a table of twenty-two integrals over one fixed set of windows: eighteen windows spanning the chelated enolic hydroxyl region between δ 19.36 and 18.02, three windows in the olefinic region carrying the diene signal of myrcene and the H-3 signal of α-humulene, and the tetramethylsilane (TMS) signal, which was set to ten integration units in every spectrum. Thirteen further samples were added: five Cryo (lupulin-enriched) pellets of US cultivars, six New Zealand hops including three harvests of Wakatu, and two harvests of the experimental cultivar HBC 1019. Because no calibrant was added to the sample tubes, the absolute scale was established indirectly. Dimethyl sulfone (DMS) was weighed into 800 µL of each of the two bottles of TMS-containing CDCl₃ that had been used for the extractions, the DMS integral was recorded with the TMS signal set to ten, and the same 800 µL volume was used for every extraction, so that the TMS signal of each sample spectrum could serve as a transfer standard carrying the DMS calibration of its bottle. The spectrum of the ASBC ICE-4 calibration extract was recorded in the same campaign.
The addendum has five objectives. The first is to carry out the quantitative NMR calculation for all 49 samples on the basis of the TMS-transferred DMS calibration, and to test, against the α-acid contents declared on the packages, the assumption that samples 038–050 were extracted with the second bottle (8.74 mg of DMS in 800 µL), with the instruction that those samples be withdrawn from the quantitative analysis if the comparison should show the assumption to be wrong. The second is to audit the integration windows and the assignments of v1.1 against the spectra, which were not available when those assignments were made. The third is to establish the uncertainty of the new calibration route and the ways in which it can fail. The fourth is to apply chemometric methods, principal component analysis (PCA), hierarchical cluster analysis (HCA), uniform manifold approximation and projection (UMAP), t-distributed stochastic neighbor embedding (t-SNE), support vector machines (SVM), partial least-squares discriminant analysis (PLS-DA) and several other classifiers, to two views of the same measurements, the integrals as recorded and the quantified chemical components, with an explicit comparison of pretreatments and with groupings examined by chemistry and by geographic source. The fifth is to state what the new data confirm, revise or overturn in v1.1, so that the addendum can later be incorporated into the main paper.
The addendum is written to stand alone, but it does not repeat the background of the main paper on hop chemistry, the published assignments of the bitter acids or the literature on quantitative NMR of hops,1–4 which should be consulted for those subjects. Sections, tables and figures are numbered with the prefix A so that they can be inserted into the main paper without renumbering. All input data, calculations and outputs are provided in the companion workbook, and the three-dimensional score plots are provided as an interactive file that runs in any web browser.
References Cited in This Section
Numbered as in the full list on the References page.