Spin Track – Benchtop Time-Domain NMR Analyzer
Analyzer is designed to perform:
- All standard NMR applications
- Development of new NMR-based techniques
- Teaching quantum physics, NMR, analytical chemistry in Universities and Colleges
NMR analyzer Spin Track comprises functional parts (probes, preamplifier and duplexer, TX Power Amplifier, Sequence Generator and PC Interface, Data Acquisition System, NMR Transceiver) which can be purchased separately and used for the specific needs of an advanced customer (see example of connection assembly). Depending on the required magnet system the Spin Track can be used as an NMR relaxometer or high resolution NMR spectrometer.
Basic characteristics of Spin Track Analyzer
Spin Track NMR-analyzer console specification:
Spectrometer mainboard | Frequency range: 1 kHz – 100 MHz |
Sequence time resolution: 20 ns | |
Frequency resolution: 1 Hz | |
Pulse sequence: Fully programmable | |
ADC bits: 14 or 16 | |
Programmable RF-pulses phase shift step: 50 | |
PC connection: Full Speed USB 2.0 | |
Preamplifier | Gain: 30 dB |
Input / Output impedance: 50 Ω | |
Noise figure: <1.5 dB | |
Ringing time: <7 µs | |
Power amplifier | Input / Output impedance: 50 Ω |
Maximal output power: 300 W | |
Power Supply | Input: 220 V (50 Hz /60 Hz), 110 V on demand |
Relax Software | Supported OS: Windows 7, 8 |
Data compatibility: ASCII, Microsoft Excel® | |
Dimensions | Spin Track: 423х271,5х151 mm |
Spin Track mini (can’t be equipped with pulse gradient system): 297x210x115 mm | |
Weight | Spin Track: 9 kg |
Spin Track mini: 5 kg | |
Power consumption | 100 W |
Standard magnets specifications:
Sensor tube diameter 10 mm |
1H Frequency: 22 MHz |
Dimensions: 282 х 175 х 270 mm | |
Weight: 33 kg | |
Sensor tube diameter 18 mm |
1H Frequency: 20 MHz |
Dimensions: 282 х 175 х 270 mm | |
Weight: 33 kg | |
Sensor tube diameter 40 mm |
1H Frequency: 14 MHz |
Dimensions: 350 х 240 х 250 mm | |
Weight: 50 kg |
Software
The product software, Relax, is a powerful tool containing many standard NMR relaxation routines and applications, and can also be used to create new pulse-sequences, pulsed field gradients, gains and attenuations, post-processing methodolgies of considerable complexity. The built-in script language is based on a widespread Pascal syntax and is enriched with commands for fitting, Fourier and Laplace transforms, Low-pass filtering, etc. The script supports dialogue windows, static messages, user-defined diagrams, data manipulation procedures. Relax also allows direct processing of data obtained when utilizing Spin Track as a high-resolution NMR spectrometer.
For Quotes and General Inquiries contact John Edwards or call (203) 744-5905