Process NMR Associates
qNMR of Intact Brown SpiritsTechnical White Paper PNA-WP-2026-SPIRITS-01 · Version 1.5
Technical White Paper PNA-WP-2026-SPIRITS-01 · Version 1.5

Quantitative ¹H NMR Analysis of Intact Brown Spirits

Ethanol Strength, Volatile Congeners, Higher-Alcohol Deconvolution and Chemometric Classification of 204 Spectra of Whiskies, Rums and Brandies

JE
John C. Edwards, Ph.D.
Process NMR Associates, LLC
84 Patrick Lane, Ste 115, Poughkeepsie, NY 12603
john@process-nmr.com · www.process-nmr.com
23 October 2026
Spirits in decanters and a tasting glass beside an NMR tube in the PNA laboratory, with spectra, PCA and PLS plots
Image slot · AI photograph: whisky, rum and cognac in tasting glasses beside an NMR tube
Save the picture as img/cover-1.jpg
Sampling whiskey from an oak barrel in a rickhouse, with sample vials and oak staves
Image slot · AI photograph: oak barrels in a rickhouse
Save the picture as img/cover-2.jpg
Figure from the paper
Figure 2. Aliphatic region of the reference spectra recorded in aqueous media, aligned with an intact bourbon (Maker's Mark, S106-055, top). Every trace is scaled to its largest displayed signal, with the displayed noise limited to 1 % of the trace spacing; no trace is clipped. HDO and, in the ethanol-containing samples, the ethanol CH₃ and CH₂ lines and their ¹³C satellites are blanked. Dotted guides mark the positions of the corresponding signals in the spirits (Table 8). † No internal reference. Asterisks mark the lines of the denaturants (methanol, 2-propanol) of the ethanol used for the 3-methyl-1-butanol solution. 3-MB, 3-methyl-1-butanol; IBU, 2-methyl-1-propanol; PrOH, 1-propanol; MeCHO, acetaldehyde. Read in context

A total of 204 ¹H NMR spectra of intact brown spirits, each prepared from 175 µL of spirit, 450 µL of D₂O and 50 µL of a maleic acid stock (4.75 mg of internal standard) and acquired at 300 MHz with 7–9 µs pulses (48–62° for the 13 µs 90° pulse of the probe, against a nominal 45°) and, for most spectra, a 15 s relaxation delay, were recovered from a MestReNova project (106 spectra decoded losslessly from the native document) and from vector PDF plots (98 spectra) and were merged into a single data set of 166 products: bourbons, American rye whiskeys, Scotch, Irish, Taiwanese and other whiskies, rums, cognacs and other brandies. Ethanol was quantified from its methyl triplet against the internal standard and expressed as % ABV and % w/w through the OIML R 22 density function. Methanol was fitted together with the upfield line of the isobutanol CH₂O doublet, which lies only 0.8–1.9 Hz from it and moves closer as the alcoholic strength rises; acetic acid, ethyl acetate, succinic acid, 2-phenylethanol, formic acid, furfural, 5-hydroxymethylfurfural, acetaldehyde, glucose and sucrose were quantified by constrained lineshape fitting, with limits of quantification propagated from the noise of each spectrum through its fit model; and the four principal higher alcohols were resolved by deconvolution of the 0.825–0.915 ppm methyl envelope with globally refined chemical shifts and couplings. Chemical-shift and coupling tables, annotated spectra and statistical total correlation spectroscopy were used to support the assignments; those of formic acid, furfural and 5-hydroxymethylfurfural rest on a single signal and remain tentative. A library of 71 reference spectra of 45 pure congeners, recorded in D₂O, aqueous ethanol, D₂O–CD₃OD, CDCl₃ or DMSO-d₆ as their solubility required, and an eleven-step mixture series were aligned with the intact spirits: solvent shifts of −0.15 to +0.22 ppm make non-aqueous references unsuitable for placing signals in a spirit, aqueous references lie a median 0.018 ppm downfield of the spirit positions, and references prepared as a spirit place them within about 0.005 ppm. They supported a tentative gallic acid singlet at 7.150 ppm in 26 of 101 products and placed the whisky-lactone signals 0.16 ppm from their CDCl₃ positions, where the lactones remain below the reach of the measurement.

For the 125 labeled products with a valid internal-standard dose, the qNMR value was a median 0.8 % (relative) below the label, but the deviation proved to depend on the acquisition campaign, with medians from −16.4 % to +1.5 % for the months with three or more labeled products; the pattern points to the internal-standard dosing chain rather than to a constant physical effect, and congener concentrations expressed per hectoliter of absolute alcohol are immune to it. The maleic acid internal standard was found to esterify in the tube to monoethyl maleate (median 0.5 mol %, maximum 5.0 mol %), fixed integration windows were shown to cross-contaminate the acetic acid and ethyl acetate singlets and to over-read methanol, and a single-line methanol model was found to overestimate methanol two-fold or more in 52 of the 163 products of the chemometric set; the two-line model, checked against the isobutanol methyl doublet (r = 0.986), lowered the median methanol content from 73 to 49 mg/L. Succinic acid, 2-phenylethanol, the aldehydes and sucrose lie below their limits of quantification in most products. Four data blocks (regional integrals, adaptively binned spectra, higher-alcohol fit areas and congener concentrations) were submitted to a pre-processing screen and to PCA, UMAP, t-SNE, Ward clustering, k-nearest neighbors, support vector machines and PLS-DA under nested cross-validation. Seven-class balanced accuracies of 0.63–0.71 were obtained with radial-basis support vector machines (chance 0.14; the PLS-DA models, which alone were permutation-tested, gave p ≤ 0.016), the fitted higher-alcohol areas and the congener concentrations performing as well as the binned spectra, whose results were shown to be strongly confounded with the data route; cognac and Taiwanese single malt were recognized with recalls of 0.80–1.00, whereas bourbon and American rye whiskey were extensively confused. The binned spectra used bin edges placed in spectral valleys, because an equidistant 0.01 ppm grid cut 12 of 34 assigned lines and shifting it by half a bin cut 16, including both acetyl singlets. PLS and support-vector regression of the binned spectra against the qNMR concentrations, validated on 20 withheld products, reproduced methanol, acetic acid, ethyl acetate and the higher alcohols with R²P = 0.93–0.997 for PLS; a second round after removal of flagged and outlying calibration products lowered the validation errors significantly for acetic acid and isobutanol, most of the gain being traceable to one product prepared with half the internal-standard dose; formal tests on repeated cross-validations confirmed the 7–17 latent variables of the cleaned models for most targets, but the components beyond about the tenth were shown to draw mainly on the signals of other congeners, and models restricted to each analyte's resonances matched or improved the predictions with fewer components for succinic acid, acetic acid, 1-propanol and the total higher alcohols; the methanol calibration, which had failed in the first version of this analysis, worked only after a clipped trace had been repaired and the reference values corrected, and moving the bin edges off the methanol line reduced its error by a further third, whereas succinic acid, mostly below its limit of quantification, was predicted from correlated congeners rather than measured. Because the reference values were derived from the same spectra, these calibrations establish internal consistency rather than accuracy against an independent method. A gravimetric internal-standard protocol with campaign check standards, an inert internal standard or timed acquisition, lineshape-fit quantification with every overlapping line modeled in place of fixed windows, native-format data for every spectrum and GC-FID cross-validation are recommended.

Contents

17 pages
Front matter
·
Abstract and Document Details
The paper
1
Introduction
  • Purpose and scope
  • Organization of the report
2
Background
  • The composition of brown spirits and the origin of their congeners
  • Regulatory and authentication framework
  • ¹H NMR spectroscopy of spirits
  • Reference spectra of pure congeners
  • Principles of quantitative NMR
  • The intact-spirit spectrum as a measurement
  • Chemometric analysis of NMR data
3
Materials and Methods
  • Samples
  • Sample preparation and NMR acquisition
  • Recovery of the spectral data
  • Referencing, normalization and the common grid
  • Quantification
  • Deconvolution of the higher-alcohol methyl region
  • Alignment, binning and the chemometric data blocks
  • Pre-processing screen
  • Pattern recognition and classification
  • Regression design
  • Software and companion files
4
Spectral Assignments
  • Anatomy of an intact-spirit spectrum
  • Table of chemical shifts and couplings
  • The aliphatic region: higher alcohols, their methylene envelopes and the ethanol satellites
  • The acetyl region: acetic acid and ethyl acetate
  • Methanol, the isobutanol CH₂O doublet and the 3.32–3.37 ppm window
  • The ester region and the monoethyl maleate artifact
  • Succinic acid, 2-phenylethanol and the acid region
  • Carbohydrates, aldehydes and the aromatic region
  • Confirmation by statistical total correlation spectroscopy
  • Reproducibility of chemical shifts
5
Ethanol: Strength by Volume and by Mass
  • Results
  • Comparison with label values
  • The deviation depends on the acquisition campaign
  • Candidate causes
  • Consequences for the reported values
6
Volatile Congeners and Other Minor Constituents
  • Overview
  • Methanol
  • Acetic acid and ethyl acetate
  • Acetaldehyde, formic acid, furanic aldehydes and the oak lactones
  • Succinic acid and 2-phenylethanol
  • Carbohydrates
  • Patterns across categories
  • Regulatory benchmarks on the absolute-alcohol basis
7
Higher Alcohols by Lineshape Deconvolution
  • Fits
  • Validation of the deconvolution
  • Concentrations and ratios
  • Anomalies
8
Results
9
Chemometric Classification
  • Pre-processing
  • Is alignment necessary?
  • Principal component analysis
  • Non-linear embeddings and hierarchical clustering
  • Supervised classification
  • Confounding by the data route
10
PLS and Support-Vector Regression
  • Design and data
  • PLS calibrations
  • PLS calibrations after removal of outliers
  • Choice of the number of latent variables
  • Support-vector regression
  • What the models use
  • Window-only and window-removed models
  • Effect of pre-processing on the calibrations
  • What these calibrations demonstrate
11
Critical Assessment and Recommendations
  • The internal-standard chain
  • Relaxation and the flip angle
  • Reactivity of the internal standard
  • Integration windows versus lineshape fitting
  • Provenance of the spectra
  • Dynamic range, exclusions and limits of quantification
  • Design of the sample set
  • Circularity of the calibrations
  • What an opposing expert would raise
  • Toward a validated method
12
Counterfeit Spirits and Undeclared Additives
  • Samples and measurements
  • What the additized vodkas contain
  • Methanol, ethanol and water by internal normalization and by internal standard
  • Would the chemometric models flag them?
  • Can the absence of higher alcohols expose additized vodka?
  • Undeclared and unusual additives in the authentic products
  • Assessment
13
Conclusions
Back matter
·
References
·
Summary
Interactive
·
Interactive Score Space: Intact Brown Spirits